产品规格
BV 证书
BV_2634H07559D0
CB 证书
CB_FR_602227A
CCC 证书
CCC_2013010304615753 CCC_2004010309130463
气候耐受性
acc. to IEC 60068-2-30 和 60068-2-11 - UTE C 63-100 规范 II
线圈工作限制
(根据 IEC 60947-4-1)0.85 ... 1.1 x Uc(在 55 C 时)C
辅助电路的连接能力
带电缆末端的柔性电缆 0.75 ... 2.5 mm 硬电缆 1 ... 4 mm
连接容量主电路
带电缆末端的柔性电缆 0.75 ... 2.5 mm 硬电缆 1 ... 4 mm
连接端子(以打开位置交付)主极
M 3.5 (+,-) pozidriv 2 带电缆夹的螺丝
传统自由空气热电流 (Ith)
符合 IEC 60947-4-1,敞开式接触器 q = 40 C 26 A 符合 IEC 60947-5-1,q = 40 C 16 A
原产国
德国 (DE)
重要性
否
CSA 证书
CSA_1041746
cUL 证书
UL_20160205-E312527-10-2
数据表,技术信息
1SBC100122C0202_Ch02
符合性声明 - CE
1SBD250801U1000
保护等级
符合 IEC 60529, IEC 60947-1, EN 60529 辅助端子 IP20
DNV 证书
DNV-GL_TAE00000TX
E-nummer
3227684
EAC 证书
EAC_RU C-FR ME77 B01010
ETIM 4
EC000066 - 磁力接触器,交流开关
ETIM 5
EC000066 - 磁力接触器,交流开关
ETIM 6
EC000066 - 电力接触器,交流开关
GL 证书
DNV-GL_TAE00000TX
GOST 证书
GOST_POCCFRME77B07175
交货期
999 day(s)
LOVAG 证书
LOVAG_FR97037
LR 证书
LRS_9830011E4
最大电气开关频率
AC-1 每小时 600 次循环 AC-2 / AC-4 每小时 300 次循环 AC-3 每小时 1200 次循环
最大机械开关频率
每小时 3600 个周期
允许的最大工作高度
3000 m
机械耐久性
10 million
常闭辅助触点数量
0
常开辅助触点数量
1
NC 主触点数量
0
NO 主触点数量
3
对象分类代码
Q
根据 IEC 60947-4-1 额定分断容量 AC-3
8 x Ie AC-3
额定控制电路电压 (Uc)
50 Hz 220 230 V 60 Hz 230 240 V
额定频率
供电电路 50 Hz 供电电路 60 Hz
额定冲击耐受电压 (U imp)
8 kV
额定绝缘电压 (Ui)
根据 IEC 60947-4-1 和 VDE 0110 (Gr. C) 1000 V 根据 UL/CSA 600 V
根据 IEC 60947-4-1 额定接通容量 AC-3
10 x Ie AC-3
额定工作电流 AC-1 (Ie)
(690 V) 40 C 25 A (690 V) 55 C 22 A (690 V) 70 C 18 A
额定工作电流 AC-15 (Ie)
(220 / 240 V) 4 A (24 / 127 V) 6 A (380 / 440 V) 3 A (500 V) 2 A (690 V) 2 A
额定工作电流 DC-13 (Ie)
(125 V) 1.1 / 138 A (24 V) 6 / 144 A (250 V) 0.55 / 138 A (48 V) 2.8 / 134 A (72 V) 2 / 144 A
额定工作电压
主电路 690 V
RINA 证书
RINA_ELE128713XG001
RMRS 证书
RMRS_0507015250
RoHS 信息
1SBD350050R1000
RoHS 状态
符合欧盟指令 2002/95/EC 2005 年 8 月 18 日及修正案
短路保护装置
辅助电路 - gG 型保险丝 10 A gG 型保险丝 25 A
技术信息
220-230V 50Hz
端子类型
螺丝端子
UL 证书
UL_071301E39231
UL 认证卡
UL_E312527
产品内容
- 1 Built-In Auxiliary Contact
- Front And Side-Mounted Add-On Auxiliary Contact Blocks - Control Circuit: Ac Operated With Laminated Magnet Circuit - Accessories: A Wide Range Of Accessories Is Available.
- A 9 Contactors Are Mainly Used For Controlling 3-Phase Motors And Generally For Controlling Power Circuits Up To 690 V Ac Or 220 V Dc. The Contactors Can Also Be Used For Many Other Applications Such As Isolation
- Capacitor Switching
- Lighting. The A... Series 1-Stack 3-Pole Contactors Are Of The Block Type Design. - Main Poles And Auxiliary Contact Blocks: 3 Main Poles Standards: Devices complying with international standards IEC 947-1 / 947-4-1, and European standards EN 60 947-1 / 60 947-4-1. Electromagnetic compatibility (EMC) acc. to amendment A11 to IEC 947-1; EN 60 947-1 and amendment 2 to IEC 947-4-1 Ambient air temperature: Close to Contactor Fitted with Thermal O/L Relay -25 ... +55 C Close to Contactor for Storage -60 ... +80 C Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... +55 C Close to Contactor without Thermal O/L Relay (Uc) -40 ... +70 C Coil consumption: Average Holding Value 50 / 60 Hz 8 VA Average Holding Value 50 / 60 Hz 2 W Average Pull-in Value 50 Hz 74 VA Average Pull-in Value 60 Hz 70 VA Max breaking capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 90 A Operate time: Between Coil Energization and NO Contact Closing 10 ... 26 ms Between Coil De-energization and NO Contact Opening 4 ... 11 ms Rated operational current AC-3 (Ie): (220 / 230 / 240 V) 55 C 9 A (380 / 400 V) 55 C 9 A (415 V) 55 C 9 A (440 V) 55 C 9 A (500 V) 55 C 9 A (690 V) 55 C 7 A Rated operational power AC-3 (Pe): (220 / 230 / 240 V) 2.2 kW (380 / 400 V) 4 kW (415 V) 4 kW (440 V) 4 kW (500 V) 5.5 kW (690 V) 5.5 kW Rated short-time withstand current (Icw): at 40 C Ambient Temp, in Free Air, from a Cold State 10 s 100 A at 40 C Ambient Temp, in Free Air, from a Cold State 15 min 26 A at 40 C Ambient Temp, in Free Air, from a Cold State 1 min 50 A at 40 C Ambient Temp, in Free Air, from a Cold State 1 s 250 A at 40 C Ambient Temp, in Free Air, from a Cold State 30 s 60 A for 0.1 s 140 A for 1 s 100 A Resistance to shock acc. to IEC 60068-2-27: Shock Direction A 20 g Closed, Shock Direction B1 10 g Open, Shock Direction B1 5 g Shock Direction B2 15 g Shock Direction C1 20 g Shock Direction C2 20 g